Release time:2023-11-17 13:21:02 Hits: Current position: Home > News
This article mainly introduces:
Dominica hydraulic cylinder,swager cylinder manufacturer,swager cylinder(Dominica swager cylinder,produced by Hengyu Hydraulic Cylinder Factory)
swager cylinder are widely used in Dominica,because of long service life,smooth movement,high work efficiency.So our company has designed swager cylinder for customers from Dominica.
When installing the swager cylinder, the axial ends of the swager cylinder cannot be fixed. Due to the effect of liquid pressure and thermal expansion in the swager cylinder, there is axial expansion. If the two ends of the swager cylinder are fixed, all parts of the swager cylinder will be deformed. When disassembling the swager cylinder, it is strictly forbidden to hammer the swager cylinder and the piston surface, such as the swager cylinder hole and the piston surface is damaged, do not allow sandpaper grinding, to use a fine oil stone carefully grinding. The clearance between the guide sleeve and the piston rod should meet the requirements.
The material, shape and compression of the swager cylinder seal have a great impact on the service life and work efficiency of the swager cylinder. In addition to requiring a reliable seal, it should also have a long service life and less friction loss. At present, there are many seal manufacturers in the country, and it is also crucial to choose high-quality seals with reliable and stable quality.
The cavitation of the swager cylinder has a great influence, and to avoid it, it is necessary to use the hydraulic oil reasonably and ensure the quality of the hydraulic oil. If the anti-foam property of the oil is poor, it is easy to produce foam, resulting in cavitation. Secondly, the change frequency of oil pressure is too fast and too high, which will also directly cause the formation of bubbles and accelerate the rupture rate of bubbles. The test shows that the speed of cavitation will be accelerated in the part with high frequency of pressure change. For example, at the inlet and outlet of the swager cylinder, due to the relatively high frequency of pressure changes, the degree of cavitation is also relatively higher than that of other parts. In addition, overheating of the oil will also increase the probability of cavitation.
When the initial action of the swager cylinder is slow, please check the temperature of the hydraulic system, because in the case of low temperature, the viscosity of the hydraulic oil is large and the fluidity is poor, resulting in slow action of the swager cylinder. The improvement method is to replace the hydraulic oil with good viscosity temperature performance, and the oil temperature at low temperature can be increased by heater or heating by the machine itself, and the normal working oil temperature of the system should be maintained at about 40 ° C.
Why the lifting cylinder falling by itself?
May be there is a pressure relief point. Check and repair the following parts: whether there is oil leakage in the transparent pipe at the top of the cylinder: the cylinder oil seal is broken, and the cylinder and oil seal need to be replaced; No: The multiway valve has pressure relief and needs to be repaired. Maintenance in accordance with routine maintenance items can reduce mechanical failures: 1. Check whether the thermostat works normally. 2, check the transmission shift work is normal. 3. Check the tightness of the fan belt. 4, check whether the diesel tank oil inlet filter is blocked or damaged, and clean or replace the filter. 5. Check and adjust the valve clearance.
Why hydraulic cylinder load can not rise?
The hydraulic cylinder does not top up indicates that the pressure of the working chamber of the hydraulic cylinder is insufficient, and the following circumstances can lead to insufficient pressure: 1) The relief valve of the hydraulic system cannot establish pressure, elimination method: check whether the pressure setting screw of the relief valve is screwed to the appropriate position. If it is an electromagnetic relief valve, please check the power-on condition. 2) The hydraulic system pipeline is connected incorrectly, when P and T are connected, this must be checked and excluded; 3) Excessive leakage in the hydraulic cylinder, resulting in (only for double-acting cylinders); 3) No hydraulic oil into the working chamber of the hydraulic cylinder, elimination method: first disassemble the hydraulic pipe connecting the reversing valve and the hydraulic cylinder, and then control the reversing valve, and observe whether there is hydraulic oil flowing out of the reversing valve.